OUT (analog — VCC/2 at 0A, ±185/100/66 mV per A for the 5A/20A/30A variants)
VCC (5V — the output scale and the VCC/2 zero point follow the supply, so power it from the same 5V the ADC reference uses)
IP+ / IP− (screw terminal — the measured current path, isolated from the logic side; neither screw is marked on the board, so wire it, read OUT, and swap the two if the sign comes out backwards)
विनिर्देश
सप्लाई वोल्टेज
4.5–5.5 V (5 V typical)
Measuring range
±5 A / ±20 A / ±30 A (by variant)
Sensitivity
185 / 100 / 66 mV/A (5 A / 20 A / 30 A)
Zero-current output
VCC / 2 (2.5 V at 5 V), ratiometric
Total output error
±1.5 % at 25 °C
बैंडविड्थ
80 kHz
राइज़ टाइम
5 µs
Conductor resistance
1.2 mΩ
Isolation
2.1 kV RMS
Supply current
10 mA typical
नोट्स
Bidirectional: below VCC/2 means current flowing from IP− to IP+. The D1 LED only shows that VCC is present.
The terminal and its traces are the only parts rated for the full current — keep the measured circuit away from the 3-pin logic side.